Waveline Touch Patient Monitor with Touch-Screen

https://www.duraprohealth.com/web/image/product.template/195582/image_1920?unique=bf274c2

$ 3,418.20 3418.2000000000003 USD $ 3,798.00

$ 3,798.00

Not Available For Sale

This combination does not exist.

Product Information:

Product images shown are for illustration purposes only and may not be an exact representation of the product. If you have questions regarding product images click here. The shipping cost provided is an estimate. Actual shipping and handling costs may vary based on the destination, logistics, supply chain challenges, and other shipment requirements. The actual shipping cost will be added to the final invoice.

User-friendly touch-screen patient monitor measures ECG, SpO2, NIBP, heart rate, temperature and respiration. Offers optional dual IBP, and EtCo2.

The fully-functional Waveline Touch features a 12.1" color TFT display with a touch-screen interface. It features multi-lead ECG monitoring, ST segment monitoring and 72 hours trend data analysis.

Features:

  • New - Optional Plug-In Anesthesia Gas Module expands measurement capabilities
  • New - Bigger time stamp in upper right corner
  • New - Standby button
  • New - Revised SpO2 pitch tone is still audible when SpO2 rate decreases
  • New - Volume and Sounds are adjustable and now can be turned off completely
  • New - Option to print Numerical Data Only
  • New - Color of the waveforms can be changed
  • EtCO2 Option allows compliance with ASA
  • Available with optional dual invasive blood pressures, EtCO2, a battery and a built-in recorder.
  • 12.1" color TFT display with a touch-screen interface
  • Multi-lead ECG monitoring
  • Built-in battery (optional)
  • NIBP list display
  • OxyCRG dynamic view display
  • Built-in thermal recorder
  • Networkable with a central monitoring system via a wireless or wired network
  • S-T Segment and 72 hours trend data analysis
  • Compact design convenient for mobile monitoring
  • Drug dose calculations
  • Multi-lingual settings

Specifications:

Physical Weight & Dimensions Weight: 5kg
Height: ~11 inches
Length: ~6-1/5 inches
Width: ~12 3/5 inches
Application Neonatal, pediatric and adult patients
Operation Environment Power Source - External AC power or internal battery
AC Power - 100-240VAC, 50/60Hz, <150VA
Battery - Rechargeable Lead-Acid; Operating time under the normal condition (1 hour); Operating time after the first alarm of low battery (10 min.)
Temperature Working - 5°-40° C
Storage - -20°-65° C
Performance Specifications Display - 12.1" color TFT, Touch Screen
Resolution - 800 x 600 pixels
Trace - 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2
Indicator - Alarm indicator; Power indicator QRS beep and alarm sound
Trend Time - 72 hours
Recorder - Built-in, thermal array, 2 channels
Record - Width 48mm
Recorder - Paper 50mm
Record - Speed 25mm/s, 50mm/s
ECG Input - 3-lead ECG cable and standard AAMI line for connection
Input - (Optional) 5-lead ECG cable and standard AAMI line for connection
Lead Choice - I, II, III, aVR, aVF, aVL, V
Gain Choice - x0.5, x1.0, x2.0
Frequency Characteristic - 0.05-40 Hz
ECG Waveforms - 7 channels
Penetration Voltage - 4000VAC 50/60Hz
Sweep Speed - 12.5, 25 and 50 mm/s
HR Display Range - 30-300bpm
Accuracy - ±1% or ±1bpm, whichever is greater
Alarm Limit Range Setting - Upper limit 80-400bpm; Lower limit 20-150bpm
RESP Measure Method - RA-LL impedance
Range - 0-120 rpm
Accuracy - + 3 rpm
Alarm Upper-lower Limit Setting - Upper limit 6-120 rpm, Lower limit 3-120 rpm
Sweep Speed - 12.5 and 25 mm/s
NIBP (Suntech) Measuring Technology - Automatic oscillating measurement
Cuff Inflating - <30s-0-300 mmHg, standard adult cuff
Measuring Period - AVE<40s
Mode - Manual, Auto, STAT
Measuring Interval in AUTO Mode - 2 min-4 hrs
Pulse Rate Range - 30-250 (bpm)
Measuring Range - Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg); Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg)
Resolution - 1mmHg
Accuracy - Pressure, Maximum Mean error ±5mmHg, Max. Standard deviation 8mmHg
Overpressure Protection - Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg)
Alarm Limit Setting - SYS 50-240 mmHg, DIA 15-180 mmHg
TEMP Range - 25°-50° C
Accuracy - + 0.2 °C 25.0°-34.9° C; + 0.1° C 35.0°-39.9° C; + 0.2° C 40.0°-44.9° C; 0.3° C 45.0°-50.0° C
Display Resolution - 0.1° C
Alarm Upper-lower Limit Setting - Upper limit 0-50° C, Lower limit 0-50° C
Channel - 2 channels
Alarm Limit Setting - 10-50° C
SPO2 ASpO2 Anti-motion SpO2
SpO2% Range 0-100%
SpO2 Accuracy + 2% 70-100%, nonmotion; + 3% 70-100%, motion
Pulse Rate Range 30-250 bpm
Pulse Rate Accuracy ±2 bpm (non-motion); ±3 bpm (motion)
Alarm Upper-lower Limit Setting: Upper limit 70-100%, Lower limit 70-100%
SpO2 Probe - Red Light LED Wavelength 660nm±5nm, Infrared Light LED
Wavelength - 940nm±10nm
IBP (Option) Measurement Range - -10-300mmHg
Channel - 2 channels
Pressure Transducer Sensitivity, 5μV/V/mmHg
Impedance Range - 300-3000Ω
Transducer Sites - ART, PA, CVP, RAP, LAP, ICP
Resolution - 1mmHg
Accuracy - ±1mmHg or ±2%, whichever is greater
Alarm range - -10-300mmHg
EtCO2 (Option) EtCO2 Option allows compliance with ASA Standards for Basic Anesthetic Monitoring (Effective July 1, 2011)
Mode of Sampling - Sidestream
Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
CO2 Measurement Range - 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
CO2 Calculation Method - BTPS (Body Temperature Pressure Saturated)
CO2 Resolution - 0.1mmHg(0-69mmHg); 0.25mmHg(70-150mmHg)
CO2 Accuracy - 0-40 mmHg ± 2 mmHg; 41-70 mmHg ± 5% of reading; 71-100 mmHg ± 8% of reading; 101-150 mmHg ± 10% of reading; Above 80 breath per minute ± 12% of reading
Sampling Rate - 100Hz
Respiration Rate - 2-150 bpm
Respiration Rate Accuracy - ±1 breath
Response Time - <3 seconds - includes transport time and rise time
Inspired CO2 Measurement Range - 3-50 mmHg